Low energy adaptive extraction for bathrooms and WCs
Product Overview
Low energy extractor fan suitable for wall, window and ceiling applications. As a Greenwood GIP product, Samika is an intermittent fan which allows application set-up at the point of installation, e.g. choose a speed setting based on installing in the ceiling or window. Includes Greenwood SMART technology as standard.
FIND OUT MORE ABOUT GREENWOOD SMART TECHNOLOGY
Benefits
Performance
Models & Control Options
Installation
Ancillaries
Samika is a brand new concept in ventilation and the first ever intermittent fan to have adjustable speeds for varying installation applications. The philosophy behind the design of Samika LE100 was driven from the need for Guaranteed Installed Performance (GIP) to be achieved in line with Building Regulations. After all - you might see a fan and even hear a fan - but how do you know it's doing its job?
- Low energy performance using as little as 1 watt in operation
- Stylish and discreet extractor fan ideal for today's modern décor
- Six speed set up for window, wall and ceiling applications - assisting in the delivery of the correct performance
- No under ventilation because it's already calibrated for the resistance of the application in which it's installed, e.g. window
- No over ventilation becasue it's already calibrated for the resistance of the application in which it's installed, e.g. ceiling with or without ducting
- Axial fan with ultra-efficient EC motor and low voltage options
- Available with a range of controls including SMART timer and humidistat and SELV extra low voltage (LE100, LE100T, LE100HT, LE100SVT, LE100SVIHT)
- Safe and secure window installation kit available here
Wiring: Must comply with IEE Regulations
Cable: 2 core 1mm2 Ø max, 3 core 1.5mm2 Ø max
Fuse: 3 amp normally required (when fan is supplied from a 6A lighting circuit no local fuse is required)
Exhaust: Ø 100mm
Electrical specification:
220–240V~50Hz Class II
SELV 24DC Class III
Glazing: Suitable for 4–28mm
LE100 glazing hole 118mm
These are the typical ancillaries required for the installation of Samika in an apartment or house -
- ED150
- Flexiduct
- EG1/EG2
- LRB
- RAB
- FF100
- LRBK
- GG42/GG84
- EWLE100/EVLE150